Eddy Currents & Self-Inductance Lab | Physics with Atta
← Physics with Atta

Eddy Currents & Self-Inductance Lab

Drop a magnet through different tubes to see eddy currents brake it, then switch a coil on and off to measure its back-EMF.

A strong magnet dropped down a 1.0 m vertical tubeReady
Time–
Speed–
Terminal speed–
Drop time (1.0 m)–

Data table

TrialTubeMagnetDrop time (s)Top speed (m/s)
Finish a drop, then press Record. Compare all four tubes.

Controls

What is happening?

The falling magnet changes the flux through rings of the metal tube. This induces eddy currents that circulate in the metal. By Lenz’s law their fields oppose the motion: the ring above attracts the magnet and the ring below repels it.

mg − kv = ma
terminal speed vt = mg / k

k is bigger for a better conductor and a stronger magnet. A slot cuts the eddy current loops.